2018 Newest Safety medical equipment isomed427p-cx Medical Isolated Power System
Item Desciption :
According to the relevant regulations in the GB 16895.24-2005 and IEC60364-7-710, in the type 2 places (various operating room, arousal room, ICU,
cardiovascular guardianship room and others all belong to the type 2 places), medical IT power system must be used to supply power.
The isolating transformer is used to divide the unprotected and protected areas;
the IT system power is drawn out from the secondary side of the isolating transformer so as to prevent ground fault current to be produced.
Using medical IT power system is the key for safe and reliable power supply in specialized places.
Isolated power system should be used to supply power to the following equipment:
High-frequency surgical equipment, infusion pump, anesthetic equipment, patient monitoring equipment, dialysis equipment, pulse pressure machine, heart recorder, syringe pump, heart-lung machine, breathing machine, constant temperature incubator and electronic pulse rhythm regulator, etc.
SZHINO Series Medical Isolated Power System Features:
Szhion series medical isolated power supply is designed to be used in medical places which require high efficiency and low noise isolated power supply as well as medical instruments which are sensitive to noise and precise measurement equipment. The conduction decrease and electromagnetic interference (EMI) technology, ideal frequency harmonic wave and sensitive monitoring and protection design can monitor equipment and power network insulation, load, temperature and so on, can protect and monitor power network operation, will act and make an alarm when an abnormal condition appears and can interlock related equipment to make interlocking protection.
The specifications and types of products provided by us include the following range: if you have special requirements, you can contact our company
Isolated Power System Components:
A set of complete medical IT power system is consisted of five parts:
1. Insulation monitor
2. Medical isolating transformer
3. Load transformer
4. Remote alarm terminal
5. Specialized Power Supply
FAQ:
1:When i order the isolate system ,what should i take care ?
A: You should tell me you just need the main part of isolate system, or you also need order the cabinet to assemble .
B: You should pay attention to the transformer is a single-phase or three-phase. Most is single-phase.
2: how much for the cabinet and assemble service ?
We make a cabinet and installation spare part , assemble all isolate part in one case. You can connect the input power and output power. So easy. Price is 280 usd.
3: Where dose the Remote alarm terminal install ?
You can install the it in the case or nursing station.
4: if you order the case, you should take care of the 3th question , so we can make the correct case for you.
5: if you order the case, you also should tell me Cabinet height, width and thickness.
6: can i have OEM service ? Or to be the distributor ?
Yes. If you want to get more ino you can contact us .
7: how long is the order time ?
About 2 weeks
Relate picture :
Specifications
1.Medical Isolated Power System supply
2.Ensure the continuity of electricity
3.Prevent circuit leakage
Medical Isolated Power System Supplier - vibration isolation system - Nora
Medical Isolated Power System and Relevant Standards
The type 2 places of medical buildings, such as operating room, ICU, CCU and others, have very high requirements on power reliability; no matter what happens, the power supply continuity should be guaranteed to the maximum extent, otherwise, once the equipment which maintains a patient’s life is powered off, the patient’s life will be endangered. Meanwhile, weak power leakage of system and load must be prevented in these places, namely, micro-electric shock to patients by the medical equipment. Therefore, IT system must be used to supply power in the type 2 places of medical buildings.
The medical IT system of BENDER (isolated power system) which is the power supply system designed especially for the type 2 medical places in accordance with IEC60364-7-710 and GB16895.24-2005 is mainly consisted of three big parts which are medical isolation transformer, isolation monitor and external alarm display instrument, and its capacity can be selected between 3.15kVA and 10kVA. At the same time, BENDER Company also provides dual-power supply automatic switching devices used especially for medical IT system.
| SZHINO-2 Series Isolation Transformer |
- Capacity: 3.15-10kVA - Temperature sensor installed inside the windings - Noise < 35DB - Completely according with GB16895.24-2005 and GB19212.16
|
| SZHINO-1 Isolation Monitor |
- Insulation monitor especially used for medical IT system - Insulation monitoring, load monitoring and isolation transformer temperature monitoring functions - Liquid crystal display with LED - Adjustable range of insulation monitoring response value: 50-500kΩ - Adjustable range of overload monitoring response value: 5A-50A - Output alarm relay - RS485 interface - Built-in or external self-check button - Wiring monitoring - Guide rail installation |
| FERKA Type External Alarm Indication and Testing Instrument |
- External alarm and display device of insulation monitor - LED displaying insulation value and load condition - Buzzer sound alarm and mute button - RS485 interface - Chinese panel - Waterproof panel to be easily cleaned |
| EDS461-L-2 Insulation Fault Assessment Instrument |
- Every Instrument provided with 12 measuring channels and connected to 12 measuring current transformer - LED display - Scanning time of every channels: 10s - Test current response sensitivity: 0.2-1mA |
| W10/8000 High Sensitivity Current Transformer |
- Installed on each circuit of medical IT system - Internal diameter of current transformer: 10mm |